To install a PEX fitting, cut the tubing square, slide on the ring or clamp, insert the fitting fully and compress the connection with the right tool. The four common systems are crimp, clamp, expansion and push to connect, and each uses its own tool and fittings. Mixing parts between systems is the most common cause of leaks.
PEX is popular because it bends around corners and needs fewer joints than copper. It is a good material for repairs and new work, and our plumbing installation service uses it for many projects.
Fitting TypesFour Ways To Connect PEX
| System | How it seals | Tool needed |
|---|---|---|
| Crimp ring | A copper ring is squeezed around the tube and fitting | Crimp tool and go no go gauge |
| Clamp ring | A stainless clamp is cinched down | Cinch tool |
| Expansion | Tubing is expanded then shrinks onto the fitting | Expander tool |
| Push to connect | A fitting grips the tube when pushed in | No special tool, but check approval |
Pick one system for the whole project and use matching parts. Rings from one brand may not fit tools from another.
Get ReadyTools And Supplies
Gather before you start
- A PEX cutter that gives a square, clean cut
- The tool that matches your fitting system
- A gauge to check crimp rings if you use them
- A deburring tool for the cut edge
- Marking pen to show insertion depth
The Steps For A Crimp Joint
Cut square
Cut the tube cleanly and remove any burrs.
Slide on the ring
Place the ring about a quarter inch from the end.
Insert the fitting
Push the fitting all the way in until the tube hits the shoulder.
Crimp and check
Squeeze the ring with the tool and verify it with the gauge.
Do not skip the gauge check. A ring that is slightly off can seep slowly and wet a wall for months before anyone notices.
What Goes WrongCommon Mistakes
Cut not square
An angled cut can leave a gap at the fitting shoulder and leak.
Fitting not fully inserted
The tube must reach the shoulder or the ring grips only part of the barb.
Wrong tool
A clamp tool on a crimp ring will not seal.
Kinks and sun
A kinked tube is weak. PEX is also damaged by long sunlight exposure.
Test every joint under pressure before you close the wall. Leave the system under pressure for at least a few hours and check for drips.
Utah WintersFreeze And Cold Weather
PEX tolerates freezing better than rigid copper, because it can expand slightly. That does not make it freeze proof. A frozen line can still burst or damage fittings. Insulate pipes in garages, exterior walls and crawlspaces.
If a pipe does freeze and split, see our burst pipe repair page for the shutoff steps and what to do while a plumber is on the way.
Know Your LimitsWhen To Hand It To A Plumber
Repairs on a single line are manageable for many homeowners. A new supply system, a connection to copper or a water heater hookup is easier to get right when a plumber does it. We also handle jobs in nearby towns such as American Fork, and the areas page lists the rest.
Good PracticeTools And Habits That Prevent Leaks
Cut PEX with a proper tube cutter so the end is square. A ragged cut keeps the fitting from sealing. Slide the ring on before you insert the fitting, and check the insertion depth against the maker marks.
Use the tool that matches the system. Crimp rings need a crimp tool and a go no go gauge, while expansion systems use a different expander. Mixing parts from different systems is a common cause of leaks.
Support horizontal runs at regular intervals so the line does not sag, and keep PEX out of direct sunlight because ultraviolet light damages it. Pressure test the system before you close the walls.
Know Your LimitsWhen To Call A Plumber Instead
PEX is friendly to learn, but a few jobs deserve a professional. Connecting to a water heater, moving a main line or tying into old galvanized pipe all carry risks that show up later as leaks. Mixed metals can also corrode where they meet, and the right transition fitting depends on what is already in the wall.
Call us if you are unsure about the connection type or see green crust on old copper. We can also pressure test your finished work before you close the wall.
Questions about your own house? Call (385) 488-1892 and a person will answer.
PEX systems must be installed to the International Plumbing Code (IPC) as Utah amends it and to the pipe maker listing, so use only the fittings and tools approved for your tubing.
FAQsPEX Fitting Questions
Push to connect is the easiest, but it costs more and approvals vary. Crimp and clamp are reliable and use affordable parts.
Avoid it. Rings, tools and fittings are designed as a system and mismatched parts can leak.
Check it with a go no go gauge. A ring outside the gauge limits must be cut out and redone.
Call Lehi Building and Inspections at (385) 201-1035. Permit rules depend on the job, and you can ask about inspections.
PEX rated for potable water is widely used in homes. Check the markings on the tube.